Z6·尊龙凯时「中国」官方网站

Product catalog

AD3000-SPD air oxygen blender

Contact Us
Online Message
Detail

The air-oxygen blender SPA is a device for medical staff to usedifferent concentrations

of mixed oxygen for oxygen therapy and rescue measures. It is suitable for neonates,

especially premature infants, due to long-term inhalation of high-flow and high-concentration oxygen caused by oxygen damage and other diseases, such as It is used in the treatment of retinopathy of prematurity ( ROP ) and chronic lung disease ( CLD ). The product meets the requirements of "Guidelines for Oxygen Use in Treatment of Premature Infants and Prevention and Treatment of Retinopathy": a device with a mixture of air and oxygen must be used. During the process of oxygen therapy, it is required to strictly grasp the indications of oxygen use and the method of oxygen supply, and do a good job of monitoring and monitoring. The oxygen concentration needs to be adjusted in time according to the condition to avoid excessive fluctuations.

Product performance characteristics

/Oxygen concentration and flow rate are adjusted separately and independently, without mutual influence

/Pneumatic air control, it is a passive product, the host does not need power supply

/The oxygen concentration is continuously adjustable, and the parameters can be set directly without calculation or reference to the comparison table

/Using anti-rust alloy material, the surface is anodized

/Unbalanced air supply pressure alarm

/Long service life and easy maintenance

/Optional flow meter / inhaler

/Expand to BUBBLE CPAP

Applications:

Oxygen for resuscitation balloon, oxygen for head and face mask , nasal cannula, cannula for oxygen, oxygen supply in warm box , continuous positive airway pressure ( CPAP ), mechanical ventilation , ECMO , extracorporeal circulation and other oxygen use occasions .

Performance parameter

Oxygen concentration adjustment:          21% ~ 100%

Flow adjustment:                                      0LPM~1.0LPM

                                                                  0LPM~10LPM

Air source failure alarm:

Air supply pressure difference alarm:      air supply pressure difference ﹥ 0.1MPa, audible alarm

                                                                  Acoustic alarm at least 60s,

                                                                  noise at least 57dB (A)

                                                                  When it is normal, it stops automatically.

Performance requirements:                      in line with YY 0893-2013

Air/O2 supply:                                           0.3MPa ~ 0.4MPa

Host size:                                                  W120mm×D120mm×H170mm

Host weight:                                             about 1.6KG

Certification:                                             EN ISO13485

Website links
>1688 alibaba
> alibaba.com

> 3618med

> merchants recruiting net

>Made in China

>MedicalExpo en
>MedicalExpo cn
友情链接: